Back to Product List
SHARE PRINT

HSLR Electrified Ligature-resistant Mortise Trim

High Security Ligature-Resistant (HSLR) trim on the L Series mortise chassis offers top level behavioral health protection per NYS-OMH standards in 5 electrified functions.

 

Looking for more information? Connect with an Allegion team member for help.

Overview

Schlage offers a comprehensive portfolio of door hardware that reduces the risk of injury or death due to ligature strangulation in all areas, but the HSLR (High Security Ligature Resistant) trim is specifically recommended for high-risk applications. The patented crescent-style handle design has quickly become the standard for ligature resistance and accessibility. It is recognized by the widely-accepted New York State Office of Mental Health (NYS-OMH) Patient Safety Standard and achieves a "paperclip protection" designation on the mortise chassis. Additionally, the motorized operation is also quieter than solenoid-based designs to help contribute to healing environments. Optional key override adds an anti-barricade safety feature on two functions helping prevent self-harm situations by allowing the key to override a  thumbturn being held in a locked position. 

Ideal for use on:    

  • Any high-risk behavioral health setting doors
  • Secured-use hospital room doors
  • Detention center doors

 Heavy Duty

 Monitoring Options

 Primus Upgradeable

Schlage 101 icon

Electrified Locks

For frequently asked questions, educational resources and technical product materials visit the Electrified Locks 101 page. 

Security

  • Provides the highest level of ligature-resistance in an ADA compliant solution to positively contribute to healing environments 
  • “Paperclip Protection” designation as determined by NYS-OMH testing enables use in low-, medium- and high-risk areas
  • HSLR mortise chassis is tested and certified to ANSI/BHMA Grade 1 operational and security standards
  • UL listed for 3-hour fire door; spring-loaded fusible link inside lock case provides fail secure mode in case of fire   
  • Deadbolt functions include anti-saw pin in bolt to prevent cut-through
  • Supplied with Torx® security screws
  • Lock monitoring options include request to exit (RX), latchbolt (LX), door postion (DPS), and deadbolt (DM) (availability varies by function)
  • Patented Everest 29™ S123 keyway is provided standard which prohibits unauthorized key duplication 
  • Restricted geographically exclusive Primus upgraded security options offer advanced key control and exceptional physical security

 

Aesthetics

  • Available in 630 Satin Stainless Steel finish
  • ADA compliant - ”no pinch, no grasp”
  • See SK1 and SL1 ligature-resistant trims for other designs with more expanded finish options  in healthcare solutions
  • Quiet, motorized activation  

 

Functions

 

Installation simplicity

  • Auto detects 12 or 24V DC
  • Low maximum current draw allows multiple locks on a single power supply
  • Energy efficient low holding current 
  • Case-mounted switch allows field selectable fail safe/fail secure setting    
  • Modular design allows RX feature to be added at a later time without opening the lock case

 

Built to Last

  • Two piece anti-friction tongue in latch bolt reduces wear
  • Breakaway spindle keeps door secured in the event of vandalism
  • Every Schlage lock undergoes intensive testing to determine its ANSI grade level including: cycle, resistance, door impact, warped door and bolt strength tests 

Electrified functions listed beginning with L/LV can be ordered with or without Vandlgard option. Both functions are field selectable Electrically Locked (EL) or Electrically Unlocked (EU). Optional key override is a safety feature, available on two functions, that allows the outside key to retract the deadbolt and/or latchbolt, depending on function, to override the inside thumbturn when it is being held in the locked position. 

Keyed non-deadbolt functions

  • L/LV9092EL/EU Electrically locking/unlocking outside lever, outside cylinder
  • L/LV9093EL/EU Electrically locking/unlocking both levers, outside cylinder
  • L/LV9095EL/EU Electrically locking/unlocking both levers, double cylinder

 

Keyed deadbolt functions

  • L/LV9492EL/EU Electrically locking/unlocking outside lever, outside cylinder, inside thumbturn with deadbolt and optional key override feature
  • L/LV9493EL/EU Electrically locking/unlocking both levers, outside cylinder, inside thumbturn with deadbolt and optional key override feature

 

Other electrified function options

 

Non-electrified

Chassis

  • Case: Cold Rolled Steel (CRS) with corrosion resistant zinc dichromate plating
  • Case size: 4-7/16" x 6 1/16" x 1" (113 mm x 154 mm x 25 mm)
  • Door thickness: 1-3/4" (44 mm) standard
  • Specify handing with order

 

Trim Options 

  • Crescent style handle design in cast stainless steel
  • Large plate escutcheon: 6” x 13.17” x .32" (152 mm x 335 mm x 8 mm); cast brass
  • Handle projection from door is 2.27" (58 mm)   
  • Available 1/8" thick lock case lead lining option for use in X-ray or other rooms with radiation concern

 

Latches

  • Backset: 2-3/4" (70 mm) only
  • Armor: Standard - 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm); Optional - 1-1⁄16" x 8" x 7⁄32"  (27 mm x 203 mm x 6 mm) 
  • Deadbolt: 1" (25 mm) throw stainless steel
  • Latch: 3⁄4" (19 mm) throw stainless steel with anti-friction tongue
  • Strike: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) standard; strike lip length: 1-3⁄16" (30 mm); dust box included

 

Electric

  • Input voltage: auto detects 12-24V DC 
  • Operating mode: Fail Safe or Fail Secure via switch on chassis
  • Current draw: 12V operating voltage: Max input current requirement is 1A. 24V operating voltage: Max input current requirement is 0.4A
  • Holding current: 0.1A
  • Request to exit: modular - 3A @ 125VAC /2A @ 30VDC                         

ANSI/BHMA

  • ANSI/BHMA A156.13-2017 Series 1000, Grade 1 operational and security 
  • With FSIC interchangeable core cylinders: Grade 1 operational, Grade 2 security
  • With SFIC interchangeable core cylinders: Grade 1 operational, Grade 3 security

 

NYS-OMH

  • Patient Safety Standards, Materials and Systems Guidelines recommended by the New York State Office of Mental Health
  • Achieves highest "paperclip protection" designation

 

ICC

  • Complies with ICC A117.1 Accessible and Usable Buildings and Facilities

 

UL/cUL

  • UL 10C and CAN/ULC-S104 listed 3-hour fire door 
    • A label single doors, 4' x 10' and pairs 8' x 10'       
    • Letter F and UL symbol on latch front indicate listing
  • UL 437 listed when using Primus high-security UL 437 cylinder
  • UL 294 access control performance levels
    • Destructive attack, Level 1
    • Line security, Level 1
    • Standby power, Level 1
    • Endurance, Level IV (with DM, or LX - Endurance, Level I)  
  • ULC-S319 Class III 

 

California Fire Code

  • All levers with a return to door of 1/2" (64 mm) or less comply (formerly Title 19, California State Fire Marshal Standard)

 

Windstorm

  • Miami-Dade NOA and Florida Building Commission listings
  • Texas Department of Insurance (TDI) for impact and non-impact applications

 

BAA/TAA

  • Meets BAA (Buy American Act)

Mortise lock and cylinder front housing finish

630 Satin stainless steel

630 Satin stainless steel

Key cylinder, plug and core face finish

626 Satin chrome

626 Satin chrome

Open keyways upgradeable to Primus RP

  • Schlage Classic Obverse open keyways, including Schlage C
  • Classic Obverse keyways gain patent protection and restricted, geography exclusivity in a Primus RP cylinder 
  • Available in Conventional and FSIC cylinder formats

 

Patented keyways upgradeable to Primus XP

  • Everest 29™ S keyways include S123 (default keyway)
  • Everest 29™ T restricted keyways 
  • Everest 29™ R restricted keyways as SL cylinders in conventional or FSIC formats with the same A2 pinning style of an SFIC cylinders
  • Everest 29™ keyways gain restricted, geography exclusivity in a Primus XP cylinder
  • Available in Conventional and FSIC cylinder formats

 

Small Format Interchangeable Cores (SFIC)

  • Everest 29™ R restricted keyway family

 

Master Keying

  • Factory master keying available

Need Replacement Parts?

Get the resources you need to get in touch with an Allegion team member for Schlage replacement parts.

wrench

Additional Resources

Did You Know?

Schlage changed the game in commercial electronics by launching the AD Series platform in 2004—the first to feature interchangeable reader and communication modules.

Case Study

Allegion Insights

Understanding Ligature Risks in Health Care Facilities

The health care market, much like the nation, has paid more attention to behavioral health in the last decade. Hospitals have hired patient safety coordinators and facilities have installed hardware that’s designed to prevent injury or self-harm.

allegion logo

ALL IN ONE. ALLEGION.

As part of Allegion’s family of pioneering brands, Schlage benefits from the strength, efficiencies, resources, and integration from a global power. In turn, we pass those advantages on to you.

Allegion helps keep people safe and secure where they live, work and visit. With more than 30 brands sold worldwide, we specialize in security around the doorway and beyond. It’s the power of one.